Redding Regional Airport Runway 16-34 and Taxiway Connectors Rehabilitation and Magvar Improvements


Bid/Contract #

FAA AIP # 3-06-0194-061-2022 / (Job # 9944-33) / Bid Negotiation 5451


Awarding Agency

City of Redding


Project Location

Redding, Shasta County, CA


Bid Date

03/05/2024 at 15:00


Project Details

J. F. Shea Construction, Inc. is requesting quotes from all qualified subcontractors and suppliers including certified DBE firms for all items of work, including but not limited to:

BASE BID
1 Airfield Safety and Traffic Control
2 Construction Staking and Survey Layout
3 Temporary Haul Route Improvements
4 Airport Access and Haul Route Repair
5 Contractor Quality Control Program (CQCP)
6 Prepare Storm Water Pollution Prevention Plan (SWPPP)
7 Implement Storm Water Pollution / Pollution Prevention Plan (SWPPP)
8 Mobilization
9 Engineer/RPR Field Office
10 Install Runway Threshold Survey Monument
11 Remove and Salvage Runway / Taxiway Light Fixture, and Transformer
12 Remove Runway Light Base Can and Transformer, Salvage Light Fixture
13 Asphalt Pavement Removal
14 Cold Milling, 4-inch Depth and Stockpile On-site
15 Cold Milling, 2-inch Depth and Stockpile On-site
16 Cold Milling, Variable Depth Transition and Stockpile On-site
17 Crack Repair
18 Daily Crack Repair Mobilization
19 Asphalt Pavement Repair
20 Unclassified Excavation and Off Haul
21 Subgrade Preparation
22 RSA Grading
23 Cement Treated Subgrade, 16-inch Depth
24 In-Place Drying of Subgrade
25 Excavation of Unsuitable Subgrade
26 Multi-axial Geogrid
27 Recycled Base
28 Crushed Aggregate Base Course
29 Asphalt Surface Course
30 Asphalt Mixture Leveling Course
31 Asphalt Mixture Leveling Course for Asphalt Pavement Repair
32 Emulsified Asphalt Tack Coat
33 Marking, Initial Application, White with Reflective Media
34 Marking, Final Application, White with Reflective Media
35 Marking, Initial Application, White without Reflective Media
36 Marking, Final Application, White without Reflective Media
37 Marking, Initial Application, Yellow with Reflective Media
38 Marking, Final Application, Yellow with Reflective Media
39 Marking, Initial Application, Yellow without Reflective Media
40 Marking, Final Application, Yellow without Reflective Media
41 Marking, Single Application, Yellow with Reflective Media
42 Marking, Single Application, Yellow without Reflective Media
43 Marking, Single Application, Black
44 Surface Painted Signs, Initial Application with Reflective Media
45 Surface Painted Signs, Final Application with Reflective Media
46 Storm Drain Pipe, 12-inch, RCP Class III
47 Removal of Foreign Substances/contaminates
48 Grooving
49 Seeding
50 Remove Miscellaneous Airfield Electrical Components
51 No. 8 AWG, 5 kV, L-824, Type C Cable, Installed in Duct Bank or Conduit
52 Concrete Encased, Electrical Conduit, 1-Way 2-Inch Sch 40 PVC, Type 1 Trench
53 No. 6 AWG, Solid, Bare Counterpoise Wire, Installed in Trench Above Duct Bank or Conduit, Including Ground Rods
and Ground Connectors
54 Encase Existing FAA Conduit with Concrete
55 Airfield Sign Legend Replacement
56 Install Salvaged Elevated Runway Edge Light Fixture and Transformer on Existing Can, without elevation adjustment
57 Install Salvaged Elevated Runway Edge Light Fixture and Transformer on Existing Can, with elevation adjustment
58 Install Salvaged In-pavement Runway Edge Light Fixture and Transformed on Existing Can, with elevation adjustment
59 Install Salvaged Elevated Runway Light Fixture and Transformer on New Can
60 Existing Electrical Junction Structure Elevation Adjustment
61 Existing Electrical Junction Can Elevation Adjustment
62 Install L-853 Retroreflective Marker, Complete

Additive Alternate
1 Contractor Quality Control Program (CQCP)
2 Airfield Safety and Traffic Control
3 Construction Staking and Survey Layout
4 Mobilization
5 Implement Storm Water Pollution / Pollution Prevention Plan (SWPPP)
6 Remove Airfield Light Fixture and Base Can, Complete
7 Remove Runway Light Base Can and Transformer, Salvage Light Fixture
8 Remove Taxiway Light Base Can and Transformer, Salvage Light Fixture
9 Underground Utility Investigation and Potholing
10 Remove Existing Junction Can
11 Remove Existing Junction Structure
12 Remove Existing Airfield Guidance Sign and PCC Pad, Complete
13 Remove Existing Airfield Guidance Sign and Protect PCC Pad, Complete
14 Asphalt Pavement Removal
15 Unclassified Excavation and Off Haul
16 Subgrade Preparation
17 RSA Grading
18 Cement Treated Subgrade, 16-inch Depth
19 Crushed Aggregate Base Course
20 Asphalt Surface Course
21 Emulsified Asphalt Tack Coat
22 Asphalt Surface Treatment, P-608
23 Marking, Initial Application, Yellow with Reflective Media
24 Marking, Final Application, Yellow with Reflective Media
25 Seeding
26 Remove Miscellaneous Airfield Electrical Components
27 No. 8 AWG, 5 kV, L-824, Type C Cable, Installed in Duct Bank or Conduit
28 No. 6 AWG, Solid, Bare Counterpoise Wire, Installed in Trench Above Duct Bank or Conduit, Including Ground Rods
and Ground Connectors
29 Non-Encased Electrical Duct Bank, 1-Way 2-Inch Sch 40 PVC
30 Concrete-Encased Electrical Duct Bank, 4-Way 4-Inch Sch 40 PVC
31 Concrete-Encased Electrical Duct Bank, 6-Way 4-Inch Sch 40 PVC
32 Concrete-Encased Electrical Duct Bank, 1-Way 2-Inch Sch 40 PVC, Type 1 Trench
33 Concrete-Encased Electrical Duct Bank, 1-Way 2-Inch Sch 40 PVC, Type 2 Trench
34 Concrete-Encased Electrical Duct Bank, 2-Way 2-Inch Sch 40 PVC, Type 1 Trench
35 Concrete-Encased Electrical Duct Bank, 8-Way 4-Inch Sch 40 PVC, Type 1 Trench
36 Directional Bore Electrical Duct Bank, 2-Way 4-Inch HDPE
37 Directional Bore Electrical Duct Bank, 4-Way 4-Inch HDPE
38 Electrical Junction Can, L-868, Type C
39 Electrical Junction Structure, Aircraft Rated with Spring Assisted Cover, Size 2, 2'x3'x3'
40 Install L-862(L) High Intensity LED Elevated Runway Edge Light, Complete
41 Install L-862E(L) High Intensity LED Elevated Runway Threshold Light, Complete
42 Install L-850C(L) High Intensity LED In-pavement Runway Edge Light, Complete
43 Install Salvaged Elevated Runway Light Fixture and Transformer on New Can
44 Install Salvaged Elevated Taxiway Light Fixture and Transformer on New Can
45 Airfield Sign Legend Replacement with New Transformer
46 Install L-858 Airfield Guidance Sign LED, 1 Module, Size 2 on Existing PCC Pad, Complete
47 Install L-858 Airfield Guidance Sign LED, 2 Module, Size 2 on Existing PCC Pad, Complete
48 Install L-858 Airfield Guidance Sign LED, 3 Module, Size 2 on Existing PCC Pad, Complete
49 Install L-858 Airfield Guidance Sign LED, 4 Module, Size 2 on Existing PCC Pad, Complete
50 Install L-858 Airfield Guidance Sign LED, 1 Module, Size 2 on New PCC Pad
51 Install L-858 Airfield Guidance Sign LED, 2 Module, Size 2 on New PCC Pad
52 Install L-858 Airfield Guidance Sign LED, 3 Module, Size 2 on New PCC Pad
53 Install L-858 Airfield Guidance Sign LED, RDR, Size 4 on New PCC Pad
54 Install New Windcone Transformer
55 Airfield Electrical Vault Equipment Improvements

Deduct Quantities
56 Cold Milling, Variable Depth Transition and Stockpile On-site
57 Asphalt Mixture Leveling Course
58 Remove Miscellaneous Airfield Electrical Components
59 Marking, Single Application, Yellow with Reflective Media
60 No. 8 AWG, 5 kV, L-824, Type C Cable, Installed in Duct Bank or Conduit
61 Concrete Encased, Electrical Conduit, 1-Way 2-Inch Sch 40 PVC, Type 1 Trench
62 No. 6 AWG, Solid, Bare Counterpoise Wire, Installed in Trench Above Duct Bank or Conduit, Including Ground Rods
and Ground Connectors
63 Existing Electrical Junction Structure Elevation Adjustment
64 Existing Electrical Junction Can Elevation Adjustment
65 Airfield Sign Legend Replacement
66 Remove and Salvage Runway/Taxiway Light Fixture, and Transformer
67 Remove Runway Light Base Can and Transformer, Salvage Light Fixture
68 Install Salvaged Elevation Runway Edge Light Fixture and Transformer on Existing Can, without elevation adjustment
69 Install Salvaged Elevated Runway Light Fixture and Transformer on New Can, with elevation adjustment
70 Install Salvaged In-pavement Runway Edge Light Fixture and Transformer on Existing Can, with elevation adjustment
71 Install Salvaged Elevated Runway Threshold Light Fixture and Transformer on New Can


J. F. Shea Construction Inc. is a union signatory contractor. Subcontractors must possess a current contractor’s license, insurance coverage and worker’s compensation for the entire length of the contract. All subcontractors will be required to sign our standard Subcontract Agreement. 100% payment and performance bonds may be required. Please call if you need assistance in obtaining insurance, bonding, equipment, materials and/or supplies. Plans and specifications can be viewed at our office located at 17400 Clear Creek Road, Redding, Ca. 96001 or call for any additional needed project information. J. F. Shea Construction Inc. intends to work cooperatively with all qualified firms seeking work on this project. We are an equal opportunity employer and will work with any interested subcontractor to identify opportunities to break items into economically feasible packages. Women and Minority Employees are encouraged to apply.

J. F. SHEA CONSTRUCTION, INC.
P.O. Box 494519 - Redding, CA 96049
Phone: (530) 246-4292 Fax: (530) 246-9940
An Equal Opportunity Employer

Get in Touch

Outreach Coordinator

Stacy Dutra


Project Estimator

Logan Hanson & Trent McGrew

Telephone

(530) 246-4292


Fax

(530) 246-9940

Address

17400 Clear Creek Rd.
Redding, CA 96001


Send Message »


Free DBE Resources

Procurement, Capital Access, & Surety Bond Assistance

The U.S. Department of Transportation-supported Southwest Region SBTRC helps DBEs with Procurement, Capital Access, and Surety Bond Assistance - and much more - at no cost.

Learn more »